              • Cryogenic Milling
              • DH-S2010IN
              • 11Setting of vibrational frequency:	digital, 0 – 70 Hz (0 – 3000 min-1),Feed material:	hard, medium-hard, soft, brittle, elastic, fibrous
              • DH-S2010IN
              • Cryogenic Milling
              • 11Setting of vibrational frequency: digital, 0 – 70 Hz (0 – 3000 min-1),Feed material: hard, medium-hard, soft, brittle, elastic, fibrous
              The liquid nitrogen circulates through the system and is continually replenished from an Autofill system in the exact amount which is required to keep the temperature at -196 °C.
              Product Features
              Cryogenic Milling DH-S2010IN instrument, which is a product launched for "small samples".
              Cryogenic Milling can quickly and effectively dry or wet grind hard, soft, and elastic samples within 1-3 minutes. It can also achieve the purpose of mixing and homogenizing powder and turbid liquids. It can be used for cryogenic grinding with liquid nitrogen, as well as for biological cell disruption and DNA/RNA extraction. The types of samples that the high-throughput tissue grinder can grind include: plant tissues, animal tissues, cells, bacteria, spores, and yeasts.


              Product Applications
              Sample Types for Grinding:
              1. Within 1-3 minutes, 24, 48, and 192 samples can be quickly and effectively ground.
              2. Closed LN2-system (autofill) for enhanced safety, avoids any contact of the user with LN2.
              3. Various centrifuge tubes, PCR tube adapters, or grinding jars of different materials can be selected.
              4. 8-shaped vibration, sample grinding without dead corners.
              5. Simple and safe operation design.
              6. Exquisite and compact appearance.
              7. Screw cap grinding jar, sealed and dustproof.
              8. Screw cap grinding jar, sealed and dustproof.
              9. Suitable for dry and wet grinding of a variety of samples.
              10. Programmable cooling and grinding cycles (10 s to 99 min).
              11. 3 different grinding modes (dry, wet or cryogenic).
              12. 20 SOPs can be stored.
              13. Grinding jars of the DH-S2010IN perform radial oscillations in a horizontal position. The inertia of the grinding balls causes them to impact with high energy on the sample material at the rounded ends of the grinding jars and pulverize it. Also, the movement of the grinding jars combined with the movement of the balls result in the intensive mixing of the sample.
              homogenizer_tissuelyser
              homogenizer_tissuelyser
              Function Principle
              The grinding jars of the DH-S2010 perform radial oscillations in a horizontal position. The inertia of the grinding balls causes them to impact with high energy on the sample material at the rounded ends of the grinding jars and pulverize it. Also, the movement of the grinding jars combined with the movement of the balls result in the intensive mixing of the sample.
              The grinding jar is continually cooled with liquid nitrogen from the integrated cooling system before and during the grinding process.
              Technical Specifications  
              Applications: size reduction, mixing, homogenization, cell disruption, cryogenic grinding
              Field of application: agriculture, biology, chemistry / plastics, construction materials, engineering / electronics, environment / recycling, food, geology / metallurgy, glass / ceramics, medicine / pharmaceuticals
              Feed material: hard, medium-hard, soft, brittle, elastic, fibrous
              Size reduction principle: impact, friction
              Material feed size: ≤8 mm
              Final fineness: ~ 5 µm
              Batch size / feed quantity: max. 2 x 50 ml
              No. of grinding stations: 2
              Setting of vibrational frequency: digital, 0 – 70 Hz (0 – 3000 min-1)
              Typical mean grinding time: 30 s – 2 min
              Grinding method: Dry grinding/Wet grinding/Cryogenic grinding
              Cell disruption with reaction vials: yes, up to 96 x 2.0 ml
              Self-centering clamping device: yes
              Type of grinding jars: screw top design
              Material of grinding tools: hardened steel, stainless steel, tungsten carbide, agate, zirconium oxide, PTFE
              Grinding ball material: Alloy steel, chrome steel, zirconia, tungsten carbide, quartz sand
              Grinding jar sizes: 1.5 ml / 5 ml / 10 ml / 25 ml / 35 ml / 50ml
              Setting of grinding time: digital, 10 s – 99 min
              Storable SOPs: 20
              Power consumption: 150 W
              W x H x D closed: 380*270*490
              Net weight: 26kg
              Electrical supply data: 100-240 V, 50/60 Hz